Sulfimax GX online WATER
Online sulphide determination in water and wastewater
Product description
The Sulfimax GX online WATER continuously measures hydrogen sulphide (H2S) and sulphides in wastewater and other other aqueous samples quickly and accurately. This is important for timely and on-demand intervention in process streams and wastewater treatment procedures.

Effective gas extraction completely expels H2S from the sample. Interference from the sample matrix is virtually non-existent. The released H2S gas is directed to the highly sensitive sensor, which detects H2S in the range of 0.01 to 1000 ppm. A measurement takes 5 to 15 min, depending on the sample composition.

With the Sulfimax GX online WATER, even industrial wastewater that is basic or contaminated with hydrocarbons or ammonia can be monitored reproducibly.

Sample aspiration, all rinsing steps and the return to the pipe system are performed automatically. Configurations can be edited and results read out via remote access. The measured values can be be transmitted to on-site alarm systems via digital and analog outputs.

The Sulfimax GX online WATER as ATEX compliant version is suitable for use in ATEX zone 1 (gas) according to DIN EN IEC 60079-2.
Sulfimax GX online WATER - Analyzer for online sulphide determination
ATEX compliant version for use in potentially explosive environment
Applications
  • Online acquisition of the current sulfide concentration
  • Environmental analysis, e. g.:
- Waste water analysis for control systems (pump sump, free level or pressure water pipe)
- Landfill leachate monitoring
- Industrial sewage treatment plants
- Municipal sewage treatment plants
Advantages
  • Automatic sample dosing
  • Hardly any cross-sensitivities due to indirect method
  • Output 4 - 20 mA for integration of the H2S signal into the control system
  • Short measuring intervals allow fast reaction to changes
  • Low maintenance requirements
Features
  • Detection of the true H2S content directly in the liquid phase and thus independent of weather conditions (even in strongly basic samples)
  • Simple calibration
  • Simple, clear software
  • No cross-contamination due to self-cleaning between measurements
  • Long sensor life due to integrated regeneration processes
Technical specifications
Device Type
Main unit
Sample dosingVia transfer line
Sample volume0,01 ... 20 mL
Typical duration
5 ... 15 min.
Range
0,01 ppm ... 1000 ppm
Resolution0,1 µg abs, Output-Signal
Gas supplyInternal pump/compressed air
Gas flowUp to 50 L/h
Power supply
220 - 230 V, 50 Hz, 2A
Power consumption
250 W
Type of protection
IP 54
Dimensions (W x H x D)
600 x 720 x 370 mm
Weight
53 kg
Device control
PC integrated
Available languages
German, English
Compatible devices